GE Circuit Breaker 120V 20A
31097 Available: 2
Copper-to-copper connections, calibrated for optimum trip performance, heat resistant thermoset cases and covers, cemented calibration screw. Type THQL - 1" per pole. May be used, when marked to accept, with American Switch, Arrow Hart, Bryant, General Switch, GTE, Sylvania, most ITE, Murray, Westinghouse Type BR, Challenger, Crouse-Hinds. 15 to 30 amp 14 - 8 Cu or 12 - 8 Al AWG wire, 35 to 60 amp 8 - 3 Cu or 8 - 2 Al AWG wire. UL Listed, HACR rated. 1" module, 120/240 volt; 10,000 AIR.
…
…
GE Circuit Breaker 120V 30A
31098 Available: 3
Copper-to-copper connections, calibrated for optimum trip performance, heat resistant thermoset cases and covers, cemented calibration screw. Type THQL - 1" per pole. May be used, when marked to accept, with American Switch, Arrow Hart, Bryant, General Switch, GTE, Sylvania, most ITE, Murray, Westinghouse Type BR, Challenger, Crouse-Hinds. 15 to 30 amp 14 - 8 Cu or 12 - 8 Al AWG wire, 35 to 60 amp 8 - 3 Cu or 8 - 2 Al AWG wire. UL Listed, HACR rated. 1" module, 120/240 volt; 10,000 AIR.
…
…
BRKR GE THQL 2P 40A 2"
31104 Available: 3
Copper-to-copper connections, calibrated for optimum trip performance, heat resistant thermoset cases and covers, cemented calibration screw. May be used, when marked to accept, with American Switch, Arrow Hart, Bryant, General Switch, GTE, Sylvania, most ITE, Murray, Westinghouse Type BR, Challenger, Crouse-Hinds. 15 to 30 amp 14 - 8 Cu or 12 - 8 Al AWG wire, 35 to 60 amp 8 - 3 Cu or 8 - 2 Al AWG wire, 70 to 100 amp 6-1/0 Cu or 4 - 1/0 Al AWG wire. UL Listed, HACR rated. 120/240 volt; 10,000 AIR. 1" per pole (2" total).
…
…
GE Circuit Breaker 240V 2P 50A
31105 Available: 2
Copper-to-copper connections, calibrated for optimum trip performance, heat resistant thermoset cases and covers, cemented calibration screw. May be used, when marked to accept, with American Switch, Arrow Hart, Bryant, General Switch, GTE, Sylvania, most ITE, Murray, Westinghouse Type BR, Challenger, Crouse-Hinds. 15 to 30 amp 14 - 8 Cu or 12 - 8 Al AWG wire, 35 to 60 amp 8 - 3 Cu or 8 - 2 Al AWG wire, 70 to 100 amp 6-1/0 Cu or 4 - 1/0 Al AWG wire. UL Listed, HACR rated. 120/240 volt; 10,000 AIR. 1" per pole (2" total).
…
…
GE Circuit Breaker 125V 15A
31713 Available: 2
For GE old style load centers.120/240 volt. Takes 1/2" space per breaker.
…
…
GE Single Pole Circuit Breaker
32775 Available: 2
Copper-to-copper connections, calibrated for optimum trip performance, heat resistant thermoset cases and covers, cemented calibration screw. Nearly identical to Type THQL with the same design and performance, yet only taking up 1/2 the space, 1/2" per pole. UL Listed, HACR rated. 15 and 20 amp SWD, switching duty rated, suitable for 120 volt fluorescent lighting loads. 15 to 25 amp #14 - 8 Cu or #12 - 8 Al AWG wire, 30 to 50 amp #8 - 4 Cu or #8 - 2 Al AWG wire. 3-9/32" height x 1/2" width x 2-3/8" depth. 120/240 volt; 10,000 AIR.
…
…
GE GFCI Circuit Breaker 120V 20A
3537255 Available: 2
Designed for use on circuits where contact with water or another ground is possible while using an electrical device. One inch module, 10,000 AIR, 5 milli-amp (.005 amp) ground fault trip level. Push to test button. May be used when marked to accept with American Switch, Arrow Hart, Bryant, General Switch, GTE, Sylvania, most ITE, Murray, Westinghouse Type BR, Challenger. 60 Hz. UL Listed.
…
…